14.09.2009 14:55:00

Medtronic Study Shows Fluid Monitoring More Accurate Than Weight Measures for Heart Failure Patients

Fluid monitoring with OptiVol® Fluid Status Monitoring is a more accurate predictor of worsening heart failure compared to daily weight monitoring in heart failure patients with implantable devices, according to results released today from the FAST (Fluid Accumulation Status Trial) clinical trial. Results showed that Medtronic, Inc. (NYSE: MDT) OptiVol® Fluid Status Monitoring, which measures changes in fluid build up in the chest cavity, predicted 76 percent of future heart failure events as compared to only 23 percent detected by weight monitoring alone. In other words, OptiVol was three times more sensitive. FAST findings were presented as a late breaking clinical trial during the 13th Annual Scientific Meeting of the Heart Failure Society of America (HFSA) in Boston.

"This data shows that OptiVol Fluid Status Monitoring is a more accurate predictor of heart failure events than weight monitoring alone,” said William T. Abraham, M.D., professor of Medicine and Physiology, at The Ohio State University and FAST principal investigator. "Instead of relying on patients with implantable heart devices to weigh themselves daily, the standard of care should include the use of implantable fluid status monitoring technology to identify worsening heart failure before symptoms worsen and lead to hospitalization.” Heart failure hospitalizations cost $18.8 billion annually in the United States.¹

Following are key findings from FAST:

  • OptiVol accurately predicted 48 of 65 heart failure events in 31 patients, which corresponds to a per patient adjusted sensitivity (some patients had more than one heart failure event) of 76 percent, whereas weight monitoring detected 13 heart failure events for a per patient adjusted sensitivity of 23 percent.
  • Forty heart failure events were predicted using OptiVol, but were not detected by weight monitoring. Conversely, weight monitoring identified only five events undetected by OptiVol. Eight events were detected by both fluid and weight monitoring.
  • Fluid monitoring had an unexplained detection rate of 1.9 events per patient per year as compared with 4.3 events per patient per year with weight monitoring.
  • OptiVol data was available for nearly every day of follow-up on all patients in the trial, whereas daily weight data was not provided by patients for 24 percent of the follow up period.

"These compelling long-term results again demonstrate the clinical advantage and accuracy of OptiVol Fluid Status Monitoring in predicting worsening heart failure,” said Marshall Stanton M.D., vice president of clinical research for the Cardiac Rhythm Disease Management business at Medtronic. "With clinical trials enrolling more than 1,400 patients, strong clinical evidence shows that OptiVol identifies patients at significantly greater risk of worsening heart failure.”

About FAST

FAST is an international, prospective, double-blinded study involving 156 implantable cardioverter-defibrillator (ICD) or cardiac resynchronization therapy-defibrillator (CRT-D) patients followed for an average of 18 months at 18 centers in the United States, Canada and Hong Kong. Patients with an OptiVol fluid index crossing above 60 ohm days (units used to measure fluid index) were compared to acute weight increases of three pounds overnight or five pounds in three days. Heart failure events are defined as hospitalizations, emergency room visits, urgent care or unscheduled office visits. Heart failure events detected in this study were within 30 days of a fluid index threshold crossing or an acute weight gain. Unexplained detections were threshold crossings or acute weight gains not associated with a heart failure event.

About OptiVol Fluid Status Monitoring

OptiVol Fluid Status Monitoring is available only on Medtronic CRT-Ds and ICDs, and has been available since U.S. Food and Drug Administration approval in 2004. It uses low-level electrical pulses that travel across the thoracic cavity (the chest area encompassing the lungs and heart) to measure the level of resistance, indicating fluid in the chest – a common sign of heart failure. Since normal fluid levels vary from patient to patient, and fluid accumulation can be either slow or rapid, OptiVol’s ability to measure fluid status trends over time can provide important insights that are used in conjunction with ongoing monitoring of other patient signs and symptoms. As of Jan. 1, 2009, the U.S. Centers for Medicare and Medicaid Services have begun reimbursing physicians for their time spent monitoring heart failure patients using fluid trend data obtained from Medtronic implantable cardiac devices via a Medtronic CareLink® Network remote transmission.

About Medtronic

Medtronic, Inc. (www.medtronic.com), headquartered in Minneapolis, is the global leader in medical technology – alleviating pain, restoring health and extending life for millions of people around the world.

¹ American Heart Association, "Heart Disease and Stroke Statistics,” 2008, p. 37.

Any forward-looking statements are subject to risks and uncertainties such as those described in Medtronic’s Annual Report on Form 10-K for the year ended April 24, 2009. Actual results may differ materially from anticipated results.

JETZT DEVISEN-CFDS MIT BIS ZU HEBEL 30 HANDELN
Handeln Sie Devisen-CFDs mit kleinen Spreads. Mit nur 100 € können Sie mit der Wirkung von 3.000 Euro Kapital handeln.
82% der Kleinanlegerkonten verlieren Geld beim CFD-Handel mit diesem Anbieter. Sie sollten überlegen, ob Sie es sich leisten können, das hohe Risiko einzugehen, Ihr Geld zu verlieren.

Nachrichten zu Medtronic Inc.mehr Nachrichten

Keine Nachrichten verfügbar.

Analysen zu Medtronic Inc.mehr Analysen

Eintrag hinzufügen
Hinweis: Sie möchten dieses Wertpapier günstig handeln? Sparen Sie sich unnötige Gebühren! Bei finanzen.net Brokerage handeln Sie Ihre Wertpapiere für nur 5 Euro Orderprovision* pro Trade? Hier informieren!
Es ist ein Fehler aufgetreten!

Indizes in diesem Artikel

S&P 500 6 049,88 0,05%
S&P 100 2 923,16 0,22%
NYSE US 100 17 412,16 0,21%