18.09.2022 17:35:00

TCT 2022: SYMPLICITY HTN-3 trial data show sustained long-term blood pressure reductions with Medtronic renal denervation procedure

  • Long-term analysis from landmark renal denervation trial presented as Late Breaking Clinical Science, published simultaneously in The Lancet
  • Data add to growing body of evidence supporting the durability of the Symplicity blood pressure procedure

DUBLIN and BOSTON, Sept. 18, 2022 /PRNewswire/ -- Medtronic plc (NYSE: MDT), a global leader in healthcare technology, today announced long-term results from the SYMPLICITY HTN-3 clinical trial. Subjects who underwent radiofrequency renal denervation (RF RDN) with the first generation Symplicity™ renal denervation system, had a statistically significant reduction in office and ambulatory blood pressure compared to subjects in the sham control group. The data were presented today as Late-Breaking Clinical Science at the 34th Transcatheter Cardiovascular Therapeutics (TCT) conference, the annual scientific symposium of the Cardiovascular Research Foundation, and published simultaneously in The Lancet.

"In this long-term follow-up from the SYMPLICITY HTN-3 trial, we observed significant reductions in the blood pressures of patients who underwent treatment with renal denervation, with no long-term complications emerging from this minimally invasive procedure," said Deepak L. Bhatt, M.D., M.P.H., executive director of Interventional Cardiovascular Programs at Brigham and Women's Hospital and Professor of Medicine at Harvard Medical School; and co-principal investigator for the SYMPLICITY HTN-3 trial. "These findings provide important insights into the evolution of patients' blood pressure control, with and without renal denervation, in a scenario more akin to the real-world setting— under everyday physician management without the frequent follow up visits and monitoring that occur in research settings. The results illustrate that for certain patients with high blood pressure, despite attempts to adhere to multiple medications and modify their lifestyles, their blood pressure remains poorly controlled, putting them at risk for cardiovascular complications such as stroke."

A total of 535 patients with treatment resistant hypertension were randomized 2:1 to RDN (n=364) vs. sham control (n=171). After six months, 101 patients in the sham control arm underwent treatment with RDN (crossover group). When conducting a longer-term analysis with all available data, and accounting for control crossover patients by using their last observation carried forward (imputation), the results through three years are as follows:

  • 26.4 mm Hg reduction in office systolic blood pressure (OSBP) for the RDN group (n=219) versus a reduction of 5.7 mm Hg in OSBP for the sham control group (n=134; adjusted treatment difference: 22.1 mm Hg, p<0.0001).
  • 15.6 mm Hg reduction in 24-hour ambulatory systolic blood pressure (ASBP) for the RDN group (n=152) and –a 0.3 mm Hg reduction in 24-hour ASBP for the sham control group (n=119); adjusted treatment difference: 16.5 mm Hg, p<0.0001).
  • On average, 17.5% of RDN patients spent time in target range (TTR), a cumulative measure in which BP measures are estimated through time, vs. 8.2% TTR for sham patients (p<0.0001).
  • Medtronic Symplicity Blood Pressure Procedure1 demonstrated long-term safety in line with expected outcomes for this patient population.2

In 2014, Medtronic announced that at six-months the HTN-3 trial met its primary safety endpoint but did not meet its primary or secondary efficacy endpoints due to multiple confounding factors, including the influence of medication changes, specific patient subgroups, and procedural factors. This latest analysis of the SYMPLICITY HTN-3 trial examined the long-term safety and efficacy of RDN in hypertensive patients who were on antihypertensive medications and received treatment with the Symplicity blood pressure procedure. This included patients from the sham control arm who crossed over to RDN after the initial six-month primary endpoint analysis.

"While we did not find a significant six-month blood pressure reduction difference in RDN versus sham in HTN-3, we felt that there was much to learn by following HTN-3 patients for a longer time period, particularly in those sham patients with sustained blood pressure elevations who 'crossed over' to RDN," said Jeffrey Popma, M.D., chief medical officer for the Coronary & Renal Denervation business and the Structural Heart & Aortic business, which are part of the Cardiovascular Portfolio at Medtronic. "Using standard imputation methods for BP comparison in cross-over patients, we were pleased to see a sustained benefit in three-year blood pressure reduction in HTN-3 patients treated with RDN. This study adds important, incremental information to the totality of evidence now supporting the long-term effect of RDN in patients with hypertension. Documentation of medication compliance and improvements made to the new Spyral catheter may have the potential to further influence clinical outcomes in patients enrolled in the SPYRAL portfolio of studies."

"Combined, with more than 7,000 patients published in clinical studies, we now have a greater understanding of patient behavior and RDN impacts over the long-term," said Jason Weidman, senior vice president and president of the Coronary & Renal Denervation business, which is part of the Cardiovascular Portfolio at Medtronic. "This analysis adds to the extensive long-term, sham-controlled evidence for the Symplicity blood pressure procedure that has consistently shown a positive impact for patients, both in the absence and presence of medications. We remain deeply committed to this adjunctive hypertension treatment option and look forward to data from additional studies, including the SPYRAL HTN-ON MED extension trial, which we plan to have at the American Heart Association Scientific Sessions, subject to acceptance."

Approved for commercial use in more than 60 countries around the world, the Symplicity Spyral renal denervation system is limited to investigational use in the United States, Japan, and Canada.

About Medtronic
Bold thinking. Bolder actions. We are Medtronic. Medtronic plc, headquartered in Dublin, Ireland, is the leading global healthcare technology company that boldly attacks the most challenging health problems facing humanity by searching out and finding solutions. Our Mission — to alleviate pain, restore health, and extend life — unites a global team of 95,000+ passionate people across 150 countries. Our technologies and therapies treat 70 health conditions and include cardiac devices, surgical robotics, insulin pumps, surgical tools, patient monitoring systems, and more. Powered by our diverse knowledge, insatiable curiosity, and desire to help all those who need it, we deliver innovative technologies that transform the lives of two people every second, every hour, every day. Expect more from us as we empower insight-driven care, experiences that put people first, and better outcomes for our world. In everything we do, we are engineering the extraordinary. For more information on Medtronic (NYSE:MDT), visit www.Medtronic.com and follow @Medtronic on Twitter and LinkedIn.

Any forward-looking statements are subject to risks and uncertainties such as those described in Medtronic's periodic reports on file with the Securities and Exchange Commission. Actual results may differ materially from anticipated results.

1 Study used the first-generation Symplicity system, which included a single-electrode catheter
2 Bhatt et al. A Controlled Trial of Renal Denervation for Resistant Hypertension. The New England Journal of Medicine. 2014 March 29. 2014;370:1393-401.

Contacts:



Lauren Mueller Doran


Ryan Weispfenning

Public Relations


Investor Relations

+1-763-285-9053


+1-763-505-4626

 

(PRNewsfoto/Medtronic plc)

 

Cision View original content to download multimedia:https://www.prnewswire.com/news-releases/tct-2022-symplicity-htn-3-trial-data-show-sustained-long-term-blood-pressure-reductions-with-medtronic-renal-denervation-procedure-301626706.html

SOURCE Medtronic plc

Analysen zu Medtronic PLCmehr Analysen

Eintrag hinzufügen
Hinweis: Sie möchten dieses Wertpapier günstig handeln? Sparen Sie sich unnötige Gebühren! Bei finanzen.net Brokerage handeln Sie Ihre Wertpapiere für nur 5 Euro Orderprovision* pro Trade? Hier informieren!
Es ist ein Fehler aufgetreten!

Aktien in diesem Artikel

Medtronic PLC 77,76 1,28% Medtronic PLC